Home / All Products / Circuit breaker MCCB NSX400F LV432676 Schneider

Circuit breaker MCCB NSX400F LV432676 Schneider

Quantity
ADD TO CART
BUY IT NOW
  • Detail

    This Compact NSX400F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds an electronic Micrologic 2.3 trip unit, with 400A rating. Micrologic 2.3 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection. This 3 poles version (140mm x 255mm x 110mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. Compact NSX400F is part of Schneider Electric EcoStruxure Power architecture.

    • range
      Compact
      product name
      Compact NSX
      product or component type
      Circuit breaker
      device short name
      Compact NSX400F
      device application
      Distribution
      poles description
      3P
      protected poles description
      3t
      network type
      AC
      network frequency
      50/60 Hz
      [In] rated current
      400 A ( 40 °C )
      [Ui] rated insulation voltage
      800 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      8 kV
      [Ue] rated operational voltage
      690 V AC 50/60 Hz
      breaking capacity code
      F (36 kA) AC
      breaking capacity
      10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
      25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
      36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
      40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
      20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
      30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
      20 kA at 600 V AC 50/60 Hz conforming to UL 508
      35 kA at 480 V AC 50/60 Hz conforming to UL 508
      85 kA at 240 V AC 50/60 Hz conforming to UL 508
      [Ics] rated service breaking capacity
      Ics 10 kA 525 V AC 50/60 Hz conforming to IEC 60947-2
      Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2
      Ics 25 kA 500 V AC 50/60 Hz conforming to IEC 60947-2
      Ics 30 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
      Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
      Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
      suitability for isolation
      Yes conforming to EN 60947-2
      Yes conforming to IEC 60947-2
      utilisation category
      Category A
      trip unit name
      Micrologic 2.3
      trip unit technology
      Electronic
      trip unit protection functions
      LSoI
      trip unit rating
      400 A ( 40 °C )
      protection type
      Overload protection (long time) L
      Short time short-circuit protection with fixed delay So
      Instantaneous short-circuit protection I
      pollution degree
      3 conforming to IEC 60664-1
      Complementary
      control type
      Toggle
      mounting mode
      Fixed
      mounting support
      Backplate
      upside connection
      Front
      downside connection
      Front
      auxiliary contact composition
      Without
      mechanical durability
      15000 cycles
      electrical durability
      12000 cycles 440 V In/2 conforming to IEC 60947-2
      3000 cycles 690 V In conforming to IEC 60947-2
      6000 cycles 440 V In conforming to IEC 60947-2
      6000 cycles 690 V In/2 conforming to IEC 60947-2
      connection pitch
      45 mm
      local signalling
      LED 105 % Ir
      LED 90 % Ir
      LED ready
      long time pick-up adjustment type Ir
      Adjustable 9 settings
      long time pick-up adjustment range
      0.9...1 x Io
      long time delay adjustment type
      Fixed
      [tr] long-time delay adjustment range
      16 s 6 x Ir
      thermal memory
      20 minutes before and after tripping
      short-time pick-up adjustment type Isd
      Adjustable 9 settings
      [Isd] short-time pick-up adjustment range
      1.5...10 x Ir
      short-time delay adjustment type
      Fixed
      instantaneous pick-up adjustment type Ii
      Fixed
      instantaneous pick-up adjustment range
      4800 A
      height
      255 mm
      width
      140 mm
      depth
      110 mm
      product weight
      6.05 kg
      Environment
      overvoltage category
      Class II
      electrical shock protection class
      Class II
      standards
      EN/IEC 60947
      UL 508
      product certifications
      CCC
      Marine
      EAC
      IP degree of protection
      IP40 conforming to IEC 60529
      IK degree of protection
      IK07 conforming to IEC 62262
      ambient air temperature for operation
      -35...70 °C
      ambient air temperature for storage
      -55...85 °C

      Warranty period
      12 months 12 months
  • Customer Reviews